Full AC Motor Electric Health Monitoring using Flux, Current, Vibration & Thermal Analysis – CSI MotorView Gold
In addition to motor current analysis, Emerson's motor monitoring tools also include motor flux analysis. Monitoring the magnetic flux field of the motor provides the safety and convenience of not having to open motor control cabinets to access electrical wiring directly, and provides detection of additional electrical problems related to the motor stator that are not found in the current signature.
Temperature measurements also play an important role in the overall motor condition analysis and are incorporated into the automated analysis. The tools are non-intrusive and perform motor current analysis, motor flux analysis and temperature measurements while motors remain online. Motor signature data is transferred to AMS Suite: Machinery Health Manager for automated expert analysis, trending, comparison with results from other diagnostic technologies, and implementation of corrective actions.
|